![]() ![]() More than a mere “step-change,” the new QUICKFIRE torch features advancements in torch technology that will appeal to trade professionals and serious home improvement enthusiasts, alike: The new QUICKFIRE torch is not only clearly different in its appearance, but also it offers benefits that outdistance every other torch in the handheld torch category. New High-Performance Torch Features Compact Profile, 30% Faster Soldering Time and QUICK-START Trigger IgniterīernzOmatic introduces QUICKFIRE, a new high-performance torch that is a must-have in every professional’s and serious DIYer’s toolbox. However, no guarantee or warranty of any kind is made with regard to the accuracy of information or the suitability of the recommendations contained herein.BernzOmatic QUICKFIRE Torch and Quick Connect Gas Cylinders Other information, including date of preparation or last revision Issue date 07-August-2014 Revision date - Version # 01 All information in this Material Safety Data Sheet is believed to be accurate and reliable. Clean Air Act (CAA) Section 112(r) Accidental Release Prevention (40 CFR 68.ġ6. Other federal regulations Clean Air Act (CAA) Section 112 Hazardous Air Pollutants (HAPs) List Not regulated. SARA 311/312 Hazardous chemical Yes SARA 313 (TRI reporting) Not regulated. Superfund Amendments and Reauthorization Act of 1986 (SARA) Immediate Hazard - No Hazard categories Delayed Hazard - No Fire Hazard - Yes Pressure Hazard - Yes Reactivity Hazard - No SARA 302 Extremely hazardous substance Not listed. Serious eye damage/eye irritation Direct contact with liquefied gas may cause eye damage from frostbite.Ĭontaminated packaging Since emptied containers may retain product residue, follow label warnings even after container is emptied. ![]() Solubility(ies) Solubility (water) 2000 mg/kg Inhalation LC100 Cat 90 % LC50 Mouse 1237 mg/l, 120 Minutes Isobutane (CAS 75-28-5) 52 %, 120 Minutes 15.6 - 17.9 mm/l, 2 Hours Rat > 13023 ppm, 4 Hours 1355 mg/l Oral LD50 Rat > 3990 mg/kg Skin corrosion/irritation Contact with liquefied gas might cause frostbites, in some cases with tissue damage. Appropriate engineering controls Provide adequate ventilation and minimize the risk of inhalation of gas. NIOSH: Pocket Guide to Chemical Hazards Components Type Value Butane (CAS 106-97-8) TWA Isobutane (CAS 75-28-5) TWA 1900 mg/m3 8 mg/m3 800 ppm Biological limit values No biological exposure limits noted for the ingredient(s). ACGIH Threshold Limit Values Components Type Value Isobutane (CAS 75-28-5) STEL 1000 ppm US. Remove contact lenses, if present and easy to do. Immediately flush eyes with plenty of water for at least 15 minutes. If frostbite occurs, immerse involved area in warm water (between 100 F/38 C and 110 F/43 C, not exceeding 112 F/44 C). Get medical attention if irritation develops and persists. Skin contact Eye contact Ingestion Remove contaminated clothing immediately and wash skin with soap and water. Breed St., Chilton, WI 53014 United States Kurt Goomey PAGE 2 Manufacturer/Importer/Supplier/Distributor information Manufacturer/Supplier Address Contact person E-mail address Telephone number Emergency telephone number Worthington Cylinder Corporation 300 E. Identification Product identifier BernzOmatic Lighter Refill Other means of identification SDS number WC034 Recommended use Refilling BernzOmatic lighters Recommended restrictions None known.
0 Comments
Leave a Reply. |